Verbazend operates out of 3 data centres located in Sydney Australia, we also serve content from a 3rd location in Melbourne.

Our platform utilises Amazon Web Services for a base infrastructure needs while allowing us to quickly scale up any servers or clusters to meet our client needs.

Our Data centres boast Tier 3 Design and Facility awards. They also carry ISO 9001 & Information Security ISO 27001.

While we mainly offer infrastructure on top of Amazon Web Services, we are also able to provide dedicated rack space in multiple locations within Australia.

WHM, VPS, Reseller & Additional Services with AWS

USA – Northern Virginia (5 Locations)
USA – Northern California (3 Locations)
USA – Oregon (3 Locations)
USA – US GOV Cloud (2 Locations)
BRAZIL – Sao Paulo (2 Locations)
IRELAND – Dublin (3 Locations)

GERMANY – Frankfurt (2 Locations)

REP OF SINGAPORE – Singapore (2 Locations)

JAPAN – Tokyo (3 Locations)

CHINA – Beijing (coming soon)

AUSTRALIA – Sydney 3 Locations)

aws-map

Physical Rack Locations in Australia for Dedicated, Co-location and Physical DR

Sydney DC

S1_01_HERO

Data Centre Specs
Location: Macquarie Park
Technical Space: 5,600m2
IT Load: 11.5MW
Rack Capacity: 2,800 full size

Dedicated cages are available for extra security.

Building Overview

  • Five storey 17,650m2 building.
  • Total technical space approximately 5,600m2.
  • 2,800 rack capacity.
  • Average 1,450m2 per data hall.
  • Office and common areas approximately 1,450m2.
  • 1m raised floors in data halls and service corridors.
  • Floor is reinforced concrete with 14.4kPa floor load capacity.
  • Built to the Australian Earthquake Loading Standard AS1170. Importance Level 4 (IL4).

Power

  • Initial available power of 12MVA, increasing up to 20MVA.
  • IT load capacity of approximately 11.5MW.
  • Minimum N+1 redundancy on power supply.
  • Multiple power distribution units (PDUs) providing N+N final circuit distribution to IT racks.
  • Harmonic distortion controlled and monitored by UPS systems.
  • Full N+1 main electrical infrastructure extending to N+N at PDU level.
  • Ultimate 12+1, 1670kVA Diesel Rotary UPS [DRUPS] units on an Isolated Parallel bus for 100% no break IT and mechanical power.
  • Diverse main feeders delivered at 11kV.
  • Minimum 24 hours’ onsite fuel supply.

Cooling

  • N+1 high efficiency water cooled chillers, cooling towers
    and pumps.
  • Dual primary pipework header and distribution system.
  • Secondary pipework distribution serving data hall equipment valved and looped providing dual path.
  • Multiple redundant water pump and compressor configuration.
  • Water storage for cooling towers.
  • Leak detection system.
  • Server heat load approximately 2000W/m2.
  • N+2 Computer Room Air Conditioning (CRAC) units per data hall.
  • CRAC units supply temperature control and floor pressure control.
  • All CRAC units are fitted with dual power supplies.
  • CRAC units fitted with high efficiency electronically commutated fans.
  • All CRAC units are located in secured plant corridors outside the data halls.
  • Average cold aisle temperature of 22 +/-2 degrees.
  • Average cold aisle relative humidity of 50% +/- 15%.
  • All mechanical plant is fully backed up by DRUPS.
  • Building Management System (BMS) for monitoring of major mechanical systems.

Telecommunications

  • Diverse connectivity and underground cable pathways to the
    building.
  • Dedicated interconnect rooms for cable connections.
  • 100% carrier and vendor neutral.

Security

  • Individual credential checks prior to authorisation.
  • 24/7 onsite security personnel.
  • Biometric fingerprint security for data centre access.
  • Anti-cloning access card encryption.
  • Secure lifts between floors.
  • Intruder-resistant glass, steel mesh and solid concrete walls.
  • Secure loading dock for deliveries.
  • Extensive coverage of motion sensitive CCTV cameras.
  • Remote monitoring and control of rack access via ONEDC®.
  • Monitoring of news and weather for external security risks.

Sustainability

  • Water cooled chiller technology with variable speed compressors.
  • Indirect water-side free cooling.
  • Rain water for cooling towers.
  • Dedicated area for potential future installation of onsite generation plant (such as tri-gen or other technologies) to significantly reduce CO2 emissions.
  • Energy efficient lighting (fluro or LED) meeting AS1680.2.2 standard.
  • External walls insulated to reduce heat transmission.
  • Variable speed compressors, pumps and fans.
  • Direct free air cooling for data halls on the upper level.
  • Low volatile organic compound (VOC) materials and paint.
  • Target PUE is 1.3 at peak load.

Fire Suppression and Monitoring

  • Inert gas fire suppression system.
  • Leak detection systems.
  • Emergency warning systems throughout the building.
  • Water mist suppression system in DRUPS enclosures.
  • Distributed fire alarm controls equipment to avoid single point of failure.
  • Fully addressable analogue fire alarm system compromising Fire Indicator Panel (FIP), mimic panels, heat detection and MASDs systems.

Certifications and Standards

  • Uptime Institute Tier III certification of design documents.
  • Uptime Institute Tier III certification of constructed facility.
  • Certified to ISO 9001:2008 for the design, development and provision of secured data centre infrastructure and associated services.
  • Designed by ASIO T4 accredited consultants with ASIO T4 security and future requirements of the Protective Security Policy framework (PSPF) in mind.
  • Designed in accordance with the Telecommunications Industry Association’s (TIA) 942 standard (Tier III).

Customer Services

  • Meeting rooms and offices for shared customer hot-desking, private suites, purpose-built NOCs or SMCs, or temporary offices for the project management of larger installations.
  • Sound-resistant boardroom, featuring floor-to-ceiling backboards for workshops and planning sessions; and staging rooms for testing equipment installations.
  • Chill-out room featuring fully functioning kitchen, flat screen
    75-inch TV, lounge, gaming console, two fully reclining
    massage chairs, Foxtel® and free Wi-Fi.

Brisbane DC

B1_Hero

Data Centre Specs
Location: Brisbane CBD
Technical Space: 1,650m2
IT Load: 2.25MW
Rack Capacity: 700 full size

Dedicated cages are available for extra security.

Building Overview

  • Six storey 2,900m2 building with additional basement.
  • Total technical space approximately 1650m2 and rooftop plant.
  • 700 rack capacity.
  • 350m2 per data hall.
  • 500mm raised floors on Levels 3 to 6.
  • Floor is reinforced concrete suspended slab.

Power

  • Available power of 5MVA.
  • IT load capacity of approximately 2.25MW.
  • Minimum N+1 redundancy.
  • Dual underground 11kV Energex feeders from city power grid.
  • N+1 redundant 11kV/415V 2500kVA distribution transformers.
  • N+1 redundant 1.2MW UPS modules for data centre load.
  • 100% standby generator power (Cummins V16 60 litre quad turbo diesel with 2.25MVA output) with N+1 redundancy.
  • Full N+1 main electrical infrastructure extending to N+N at PDU level.
  • Diverse path vertical distribution cabling to data centre floors.
  • Diverse A + B + C power supply distributed at 400V via UPS.
  • Minimum 12 hours’ onsite fuel supply.

Cooling

  • N+1 air-cooled UNIFLAIR chillers with variable speed motors.
  • Dual chilled water risers servicing the building.
  • Chilled water buffer tank with dual water bypass.
  • Multiple redundant water pump and compressor configuration.
  • Redundant back-up pipe systems to essential equipment.
  • Server heat load approximately 1,400 W/m2
  • N+1 Computer Room Air Conditioning (CRAC) units per data centre room.
  • CRAC units fitted with supply temperature control and floor pressure control.
  • Cold aisle containment system on Levels 3 to 6.
  • Hot aisle containment system on Level 2.
  • Average cold aisle temperature of 22 +/-2 degrees.
  • Average cold aisle relative humidity of 50% +/- 15%.

Telecommunications

  • Diverse underground cable pathways to the building.
  • Dedicated interconnect room for cable connections.
  • 100% carrier and vendor neutral.

Security

  • Individual credential checks prior to authorisation.
  • 24/7 onsite security personnel.
  • Biometric fingerprint security for data centre access.
  • Anti-cloning access card encryption.
  • Secure lifts between floors with man trap entrance points.
  • Intruder-resistant glass, steel mesh and solid concrete walls.
  • Extensive coverage of motion sensitive CCTV cameras.
  • Remote monitoring and control of rack access via ONEDC®.
  • Monitoring of news and weather for external security risks.

Sustainability

  • Air-cooled chiller with free cooling technology reducing water consumption.
  • APC highly efficient, power protected UPS system.
  • Thermally insulated data hall floors.
  • External walls clad with aluminium composite sheeting to reduce heat transmission.
  • Low volatile organic compound (VOC) materials and paint.
  • Antistatic vinyl on Levels 1 and 2.
  • Energy efficient lighting (fluro or LED) meeting AS1680.2.2 standard.
  • PUE target is 1.6 at peak load.

Fire Suppression and Monitoring

  • Inert gas fire suppression system.
  • Leak detection systems.
  • Distributed fire alarm control equipment to avoid single point of failure.
  • Two monitored fire escapes.
  • External water sprinkler system to protect from neighbouring building fires.
  • Water misting system to protect generators from fire.
  • Fully addressable analogue fire alarm system compromising Fire Indicator Panel (FIP), mimic panels, heat detection and MASDs systems.

Certifications and Standards

  • Certified to ISO 9001:2008 for the design, development and provision of secured data centre infrastructure and associated services.
  • Designed in accordance with the Telecommunications Industry Association’s (TIA) 942 standard (Tier III).

Customer Services

  • Sound-proof customer meeting rooms.
  • Chill-out room equipped with kitchen facilities including tea and coffee and a TV.
  • Spare cables and other handy items are available in distinctive vending machines in the chill out room.
  • Information display, about the data hall environment such as temperature and humidity levels.